Highlights
Highlights
Benefits
- 37.5% efficiency in mechanical drive; up to 84% thermal efficiency in combined heat and power
- Flexible operation to 50% of rated speed; ideal in mechanical drive—can start with fully pressurized compressor
- Lower maintenance costs and 35,000 hours MTBM—automapping eliminates seasonal DLN tuning and intermediate boroscopic inspections
Features
- Rugged, high-performance axial flow compressor
- Single-row annular combustion system for best-in-class low emissions and wide fuel flexibility
- Highest efficiency over the entire power range thanks to variable-geometry low-pressure turbine nozzles technology
Applications
- Onshore and offshore
- Pipeline, gas storage
- Industrial, and combined heat and power
Featured Video
Featured Video
Overview
Overview
The NovaLT™16 gas turbine draws on our latest innovations combined with the best proven technologies and fleet experience from our entire gas turbine portfolio.
Specification
Mechanical drive
Power (MW/HP)
17.5/23,500
Efficiency (%)
37.5
NOx emissions (ppm)
15*
Exhaust temperature (ºC/ºF)
495/923
Speed (rpm)
3,900-7,800
Hot gas path inspection (hours)
35,000
Major inspection (hours)
70,000
Package dimensions (m/ft)
12.5x3.1x4.1/41x10.2x13.5 (LxWxH)
At ISO conditions with natural gas fuel, ambient temperature 15ºC, no inlet or exhaust losses, sea level, 60% relative humidity. Package dimensions exclude driven equipment.
* 9 ppm upon request
Specification
Power generation (50/60 Hz)
Power (MW)
16.9
Efficiency (%)
36.4
NOx emissions (ppm)
15*
Exhaust temperature (ºC/ºF)
495/923
Speed (rpm)
3,900-7,800
Hot gas path inspection (hours)
35,000
Major inspection (hours)
70,000
Package dimensions (m/ft)
15.6x3.1x4.1/51.2x10.2x13.5 (LxWxH)
At ISO conditions with natural gas fuel, ambient temperature 15ºC, no inlet or exhaust losses, sea level, 60% relative humidity. Package dimensions include driven equipment.
* 9 ppm upon request
The best from two worlds
NovaLT™16 gas turbines blend the robustness of our frame technologies with the modular maintenance capabilities of our aeroderivatives.
Extended maintenance plan
The NovaLT™16 gas turbine is designed for up to 35,000 hours mean time between maintenance (MTBM) without boroscope inspections, and targeting 24-hour engine swap. Real-time condition monitoring anticipates and helps prevent problems. If problems do occur, 24/7 product support service is available.
DLN automapping
Thanks to automapping, dry low emission (DLN) tuning is required and performed only during commissioning (which is 90% faster than for a traditional system), and every four years thereafter via remote connection with our RM&D Centers.
Hydrogen for energy transition
NovaLT™16 gas turbines can burn up to 30% hydrogen in DLN mode, and we’re moving toward 100% H2 capability.