Panametrics, a Baker Hughes business, offers industrial oxygen and gas analyzers that improve process efficiency, optimize reactors, and provide greater confidence for petrochemical, power generation, and combustion efficiency applications. These solid-state oxygen and gas analyzer designs use no moving parts, ensuring reliable measurement even in difficult, high-noise environments.
From the microprocessor-based XMTC, perfectly suited for measuring the concentration of binary gas mixtures including hydrogen, carbon dioxide, methane, helium, and more, or the explosion-proof design of the XDP, certified for use in Class I, Division 1, Groups B, & D, and II 2 GD EEx d IIC T6 hazardous areas, to the minimalist, mount-anywhere design of the Panametrics oxy.IQ, we're confident that if you need an industrial oxygen and gas analyzer in your production environment, we have an accurate and reliable solution for you.
Rugged and compact, the Panametrics XMO2 transmitter can be used to provide computer-enhanced, drift-free oxygen measurement. This transmitter offers accuracy and reliability for long-term oxygen measurements that are critical to your process and product quality.
The XMO2 combines computer-enhanced, automatic oxygen signal compensation, fast-response software, real-time error detection, and automated calibration with a proven thermoparamagnetic oxygen sensor to achieve unequaled performance and ease of use. Features include:
- Measurement ranges from 0.01 percent to 100 percent O2 in gases
- Explosion-proof and flameproof enclosure with weatherproof protection allows sensor to be remotely mounted at the measurement point
- Push-button, single or dual gas calibration
- Compact, rugged sensor design with no moving parts provides long term reliability and trouble-free operation
- Dual-bridge measurement circuit compensates for variations in background gas composition
- Unique dual-chamber,temperature-controlled cell design provides resistance to contamination and flow fluctuation
- Computer-enhanced accuracy of 1 percent of span and linearity of better than 0.5 percent of span
- Automatic background gas compensation
The Panametrics oxy.IQ contains a built-in microprocessor and is designed to fit easily into any installation site. The oxy.IQ is a highly reliable and cost-effective two-wire, loop-powered transmitter with a linearized 4 to 20 mA output.
It measures oxygen in ten ppm ranges and seven percentage ranges. All ranges are user-selectable. This compact transmitter uses proven sensor technology to accurately measure O2 in a variety of gases. The oxygen analyzer serves both general purpose and hazardous areas with an intuitive interface for easy programming.
Features include:
- Two-wire, loop-powered 4 to 20 mA transmitter
- Display with keypad
- Intrinsically safe option for Class 1 Div 1 and Div 2 locations, and ATEX/IECEX Zone 0
- Non Incendive for Div 2 locations
- Ex flameproof option
- Proven galvanic fuel cell O2 sensor technology
- User-selectable ranges for ppm and percent oxygen
- User-friendly and intuitive user interface with diagnostics
- Microprocessor-based, all-digital technology for reliable operation
- Low maintenance, economical and compact
- Sensor failure output error
- Sensor lifetime indication
- NAMUR error indication
The Panametrics microprocessor-based XMTC is a compact, rugged, online thermal conductivity transmitter that measures the concentration of binary gas mixtures including hydrogen, carbon dioxide, methane, helium and many others.
The analyzer also combines computer-enhanced signal measurement with fast-response software, real-time error detection, and digital communication via an RS232 or RS485 interface.
The XMTC thermal conductivity transmitter and analyzer are ideal for hydrogen and gas applications, along with industries such as metals, electric power, petroleum, chemical, methane, landfill, biogas, gas production, and food. Features include:
- Ultra-stable glass-coated thermistors
- Single or dual gas push-button calibration
- PC interface package for digital output
- Type IP66/4X construction
- ATEX, IECEx, FM and CSA certified for Zone I and Division 1 hazardous areas
The Panametrics XDP explosion-proof display provides the measurement of percent or ppm oxygen or hydrogen gas. The explosion-proof XDP is certified for use in Class I, Division 1, Groups B, & D, and II 2 GD Exd IIC T6 hazardous areas. Features include:
- Explosion-proof for Class I, Division 1, Group B, C & D hazardous areas
- Flameproof II 2 GD Exd IIC T6 T85°C
- Magnetic through-the-glass keypad
- Universal AC input
- 24 VDC power supply for XMO2, XMTC or OXY.IQ
- Software for measurement of percent or ppm oxygen or hydrogen
- Three-curve software for hydrogen-cooled generator
- Programmable process relay contacts
Auto-verification/Auto-calibration
The XDP provides long-term, hands-off operation with this optional feature. When initiated, the XDP controls solenoid valves in the sample system to bring zero and span gases to the transmitter. Then the XDP software compares calibration gas readings with factory data to verify proper calibration. If an adjustment is necessary, the XDP makes corrections automatically and notifies the user via the front panel display and alarm contacts.
The Panametrics TMO2D is an optional display and control module that enhances the performance and operation of transmitters such as the XMO2, XMTC, or oxy.IQ.
It provides a two-line x 24-character backlit LCD display, display and option programming via keyboard, recorder outputs, alarm relays, and relays for driving sample system solenoids for automatic zero and span calibration, as well as a 24 VDC power supply for the transmitter.
Features include:
- Two-line x 24-character backlit LCD
- Single or dual isolated, 4 to 20 mA outputs
- Up to four field-configurable process alarms
- Automatic calibration relays
Optional Autoverification/Autocalibration
The TMO2D provides long-term, hands-off operation with this optional feature. When initiated, the TMO2D controls solenoid valves in the sample system to bring zero and span gases to the transmitter. Then TMO2D software compares the calibration gas readings with factory data to verify proper calibration. If an adjustment is necessary, the TMO2D makes corrections automatically and notifies the user via the front panel display and alarm contacts.
O2.IQ simplifies and standardizes your options for reliable oxygen measurement in a variety of applications. At the heart of this package is the oxy.IQ analyzer supported by a sample conditioning system purposefully designed to maintain ease of access and functionality in a space conscious housing. Simply mount the O2.IQ, connect to the two terminals and the analyzer is ready for its field calibration. Key highlights include:
- Wall mounted NEMA 4X and IP66 stainless steel package
- Features the oxy.IQ electrochemical analyzer
- Package designed with ease of access including accessibility to sensor cell replacement
- Sample conditioning system provides isolation, filtration, pressure regulation, flow and pressure indication along with a clear window for easy viewing of all readings.