PTX400



Product Overview
Pressure Measurement

Operating Pressure Ranges
Any full scale range may be specified between
0 - 1035 bar/15,000 PSI sealed gauge or absolute.
Please contact Druck for more information.


Proof Pressure
Proof pressure tested to 1.5 x F.S.


Overpressure
The operating pressure range can be exceeded by
upto 1.5 x F.S. without degrading performance.


Secondary Containment Pressure
The transmitter will safely contain up to 1553 bar
maximum without leakage of pressure media.


Process Media Compatibility
Fluids compatible with a fully welded assembly of
Inconel 625
 

Temperature Measurement

Operating Temperature Ranges 
Suitable for -46°C to +150°C.

Electrical Connection

Transmitter Supply Voltage
9 to 36 VDC. The minimum supply voltage that must
appear across the transmitter terminals is 9 VDC and
is calculated by: VMIN = VSUP - (0.02 x RLOOP).
Protected to 38V inverse polarity.


Supply Sensitivity
<0.005% F.S./Volt.


Insulation Resistance
> 1GΩ at 50 Vdc VDC


Output Current

  • 4 to 20mA proportional loop powered output for specified operating pressure or temperature range.
  • CANbus to Cia 443 CAN OPEN profile for SIIS Level 2. Power consumption 0.85W per channel. Inrush current >40mA in 300msec
  • Modbus RS485 output also available

Please contact Druck for more information.

Performance

Accuracy
Combined Non-linearity, Hysteresis, Zero and Span,
Repeatability and Thermal Errors:
Pressure: < 0.1% F.S. (B.S.L)
Temperature: 0.2% F.S. typical.


Long Term Stability
At standard reference conditions the calibration will
not exceed +/-0.1% F.S. per annum.


Temperature Range
Process/Fluid Temperature -46°C to 150°C
Compensated -46°C to 150°C
Storage -55°C to 70°C

Physical

Process Connections Available

  • 15,000 psi API 2 1/16” flange to API 6A-6BX BX152
  • 10,000 psi API 2 1/16” flange to API 6A-6BX BX152
  • 10,000 psi API 1 13/16” flange to API 6A-6BX BX151

 With pressure tapping.


Electrical Connection
Compatible with a wide range of proprietary
subsea connectors. Please contact Druck for more
information.


Weight
17 kg nominal.


Ingress Protection
IP68, submersible to 3360 mH2O.


Safety
EMC emissions EN50081-1
EMC Immunity EN61000-6-2
Certification CE marked

Datasheet

Datasheets - PTX 400 Series



Contact Us | Support

For more information on Druck products or to reach a member of your local Druck team please click > here

You can contact the Druck Support Team > here